HCMP430TS - Wye-Delta Open Transition Start with transfer switch
Maximum Philippines
Regular price
₱0.00
Metron/Metron-Eledyne Fire Pump Controllers conform to the latest requirements of National Fire Protection Association's Standard for Centrifugal Fire Pumps as adopted by Underwriters Laboratories and Factory Mutual. They are withstand rated and listed by Underwriters' Laboratories and approved by Factory Mutual Research Corporation. Sizes range from 15 to 700 horsepower, 200 to 600 volts (480 volts max. when supplied with transfer switch), 60 Hz. These controllers are for use on Reduced Voltage type installations. Only the highest quality components, all UL listed or UL recognized, are used throughout to assure the best possible reliability. The cabinet is fabricated of heavy gauge reinforced steel with drip-proof hood. All field wiring and service connections may be made from the front, allowing the controller to be mounted flush against a wall. The controller is completely wired, assembled, and tested at the factory before shipment, and ready for immediate installation. Wye-Delta motors have all six leads brought out to the motor terminal box. These leads are connected by the contoller first in the Wye configuration which draws only 33% of normal starting current and develops 33% of normal starting torque. After a short time delay, the controller then connects the motor winding in a Delta configuration, applying full voltage and drawing full load running current and developing full running torque.With the M430 open transistion types, there is a very short period of time where no voltage is applied to the motor during transition from Wye to Delta connections. This condition can cause current surges or disturbances fed back into the main power source. The magnitude of the surges is proportional to the phase difference between the voltage generated by the running motor and the power source. These transients can in some instances affect other equipment which are sensitive to current surges.Metron/Metron-Eledyne Wye-Delta Controllers incorporate a mechanical as well as electrical interlock to prevent the Wye connecting contactor from being energized at the same time as the Delta contactor.An emergency start lever is provided to close the starting contactors independent of automatic control circuits. When used, this lever will bypass the reduced current start feature and start the motor with full inrush current drawn from the power source
For More Information:
Call +63 917 594 0206 / 02 7092 4489 / 02 8710 1965/ +63 506 0226
Or Email Us :
maximumbuilders.ph@gmail.com
maximumengineering2011@gmail.com
albertgregore26@gmail.com
people are currently looking at this product
Estimated delivery time 5-10 days
Guaranteed Safe Checkout